Supercapacitors
Store charge as a layer of ions on the electrode surface. They deliver and accept high power within seconds and tolerate very large cycle counts, but hold relatively little energy.
Built for seconds to tens of seconds

Our software splits the demand above a grid limit. Supercapacitors take the brief bursts, batteries take the rest.
Both are built from the same sodium-ion energy module and supercapacitor power module, so a site can start small and grow. Each system is sized for its site.
| System | Typical sites | Footprint | Scale |
|---|---|---|---|
| Rack systems | Telecom sites, network cabinets and smaller commercial buildings, in standard 19-inch racks | One or two racks | Tens of kilowatt-hours |
| High-capacity systems | Data centers, EV charging hubs, industrial plants and grid support | Multiple bays, added as the site grows | Hundreds of kilowatt-hours and up |
Our system combines sodium-ion batteries, supercapacitors and control software, each taking the part of the demand it suits.
Store charge as a layer of ions on the electrode surface. They deliver and accept high power within seconds and tolerate very large cycle counts, but hold relatively little energy.
Built for seconds to tens of seconds
Store energy by moving sodium ions into and out of the electrode material. They supply the longer part of a demand peak and hold far more energy than the same volume of supercapacitors.
Built for minutes to hours
Compare site demand with the grid limit, send short events to the supercapacitors and sustained demand to the batteries, then recharge both when there is headroom.
Continuous
The software reads site demand and decides which one answers, moment by moment.
Our storage sits on the DC side of a power converter, which moves energy to and from the AC system you already run. We build the batteries, the supercapacitors and the software that decides what happens. The converter and the site wiring come from your integrator, and we design around them.
Ask for specifications and test documents for the exact equipment: usable energy, charge and discharge limits, operating conditions, protection and installation requirements.
Four decisions that shape everything else in the design.
Our cell suppliers rate the sodium-ion cells and supercapacitor modules from −40 °C to +65 °C. Arctic cabinets and desert rooftops are the point. The rating for a complete system also depends on its enclosure.
Cells that run cooler need less cooling around them: less chiller energy, less water, and simpler mechanical work in the building.
The battery cells use no lithium, cobalt or nickel. Sodium compounds are produced in many regions from common raw materials.
Supercapacitors take the fast, high-power events, so the batteries run at a steadier rate instead of chasing every spike.
Three independent tracks, run by people who do not work for us. Dr. Zaghib also sits on our advisory board.
The peak-shaving simulator runs this split on four example sites and compares it with a battery-only design.