Skip to content
Blue Planet Energy

Battery 101

A guide to battery capacity, power, charging, service life and safety terms. Most of it applies to any battery chemistry.

On this page

The basics

How a battery works

This simplified diagram shows ions moving in a sodium-ion cell. Most rechargeable batteries share the same basic parts.

Cross-section of a battery cell. Between two current collectors sit the anode, a separator soaked in electrolyte, and the cathode. Use the Discharge and Charge buttons to move the ions between the electrodes.

State of charge100%

Charged to the upper operating limit. The moving ions are stored in the anode.

Anode and cathode
The two electrodes. During discharge, ions move from the anode to the cathode through the electrolyte. Electrons flow from the anode through the external circuit to the cathode, powering the load.
Electrolyte
The material the ions move through inside the cell. It carries ions but not electrons, which forces the electrons out through the circuit.
Separator
A thin porous film between the electrodes. It lets ions pass and keeps the electrodes from touching and short-circuiting.
Current collectors
Thin metal foils that carry electrons into and out of each electrode.

Charging runs the process in reverse. The charger pushes ions back into the anode, storing energy for the next discharge.

A cell's voltage comes from the chemistry of its two electrodes. Its capacity comes from how many ions the electrodes can hold.

How each one stores charge

Batteries and supercapacitors store energy differently. The difference is where the charge goes.

Sodium-ion cell

Charging pulls sodium ions out of the cathode, across the separator and into the carbon anode. Discharging sends them back while electrons flow through the external circuit. Moving ions into solid material stores a lot of energy, and it takes time.

Supercapacitor

In a supercapacitor like the one shown, charge is stored by ions gathering along the surface of porous carbon, positive ions on one side and negative ions on the other. That layer forms and clears quickly, but a surface holds far less energy than a bulk material.

Not to scale. The speeds here are for clarity, not performance figures.

Cells, modules and racks

A cell is the smallest working unit: two electrodes, a separator and electrolyte in a sealed case. Its voltage is set by its chemistry. Cells are wired into modules, modules into racks, and racks into a system.

SeriesAdds voltage. Four 3 V, 100 Ah cells in series make 12 V at 100 Ah.
ParallelAdds capacity. The same four cells in parallel make 3 V at 400 Ah.

Power and energy are different things

Power, in kilowatts (kW), is how fast energy moves. Energy, in kilowatt-hours (kWh), is how much is stored. Picture a water tank: kWh is the size of the tank and kW is the width of the pipe. A 100 kW system running for two hours delivers 200 kWh.

A site with short, sharp peaks mostly needs power. A site moving solar output into the evening mostly needs energy. That difference decides what gets built.

C-rate: how hard a battery is worked

C-rate is current divided by rated capacity in ampere-hours. For a 100 Ah battery, 100 A is 1C. Ideally a full discharge takes one hour at 1C, 30 minutes at 2C and two hours at 0.5C; actual usable capacity depends on operating conditions. Higher rates mean more current and more resistive heating, which can speed up wear. Supercapacitors help here: they take the brief high-rate pulls so the battery can run at a gentler rate.

Ideal full-discharge time
1 h
Current compared with 1C
1×
Resistive heating power compared with 1C, at constant resistance
1×

State of charge: 100%

State of charge and depth of discharge

State of charge (SoC) is how full the battery is, as a percentage. Depth of discharge (DoD) is how much of it a cycle uses. Systems usually hold a reserve at the top and bottom, so usable energy is lower than the capacity printed on the cells. Compare quotes on usable kWh.

Performance and service life

Round-trip efficiency

Round-trip efficiency is the energy you get back divided by the energy you put in, measured at a stated point such as the AC meter. Losses come from the cells, the power electronics and cooling. Every point of efficiency is energy that is not wasted on each cycle.

Cycle life and calendar life

Batteries age from use (cycle life) and from time (calendar life). A backup system that rarely discharges ages mostly with the calendar. In a system that cycles daily, cycling and calendar aging both matter. Their relative weight depends on temperature, state of charge, depth of discharge and cell design.

A cycle-life number means little without its conditions: depth of discharge, C-rate, temperature and the capacity that counts as end of life.

AC, DC and power conversion

Batteries store chemical energy and deliver direct current (DC) electrical power. The grid and most buildings run on alternating current (AC). A bidirectional power conversion system (PCS), built around an inverter, exchanges power between the two and controls how fast power flows each way.

DC is harder to interrupt. AC current crosses zero every half cycle, which helps an arc go out. DC has no natural current zero, so its switches, breakers and fuses must be rated for DC.

Low-voltage and high-voltage systems

The same power at a higher voltage needs less current. Less current means smaller cables and lower resistive losses, which grow with the square of the current. The trade-off is stricter insulation, spacing and safety requirements. Small systems often stay below about 60 V DC. Commercial and utility systems commonly run between 400 and 1,500 V DC.

The battery management system

The battery management system (BMS) monitors cell-group voltages, pack current and temperature sensors. It manages balancing and works with the rest of the system to set charge and discharge limits and trigger protective shutdowns.

Safety and standards

Safety terms worth knowing

Thermal runaway
A cell overheats, the heat drives reactions that release more heat, and the failure can spread to neighboring cells. Chemistry, system design and spacing all affect how likely and how severe it is.
UL 9540
A product safety standard for energy storage systems and equipment.
UL 9540A
A test method for evaluating thermal runaway and fire propagation. Its results inform installation requirements. Passing it is not the same as a UL 9540 listing.
NFPA 855
An installation standard for stationary energy storage. What applies depends on the codes and editions adopted locally.

Terms and next steps

Other terms you will hear

Battery energy storage system (BESS)
The whole installation, not just the cells: batteries, power conversion, controls, protection and safety equipment.
Blended or hybrid storage
A system that combines more than one storage technology so each covers what it does best, such as batteries for energy and supercapacitors for short bursts of power.
Demand charge
A charge based on the highest power a site draws during a billing period, not the total energy used. It is a separate line from the per-kilowatt-hour energy charge.
Peak load and peak shaving
A peak load is a period of unusually high demand. Peak shaving means supplying part of that demand from storage so less is drawn from the grid.
Energy density
How much energy a cell stores for its weight or volume, in watt-hours per kilogram or per liter. It matters most where space and weight are tight.
Grid-scale storage
Large systems operated by utilities or big facilities to balance supply and demand, support renewable generation and hold reserve.
Virtual power plant
Many small resources, such as batteries and solar systems, coordinated by software so they act together like one larger plant.

Three questions to start a storage assessment

  1. What are you solving: a power limit, an energy shortfall, or both?
  2. How long does each event last: seconds, minutes or hours?
  3. How often does it happen: a few times a year, every day, or every few seconds?

Short, frequent, high-power events point to supercapacitors. Long events point to batteries. Sites with both are candidates for comparing hybrid storage, battery storage and load management.

See it on a simulated site